FixVault

Variable Valve Lift Diagnosis Oil Pressure Switch: Installation

Install in the reverse order of removal.

NOTE: Apply liquid gasket to the variable valve lift diagnosis oil pressure switch threads.

Liquid gasket: 

THREE BOND 1324 (Part No. 004403042) or equivalent 

Tightening torque: 17 N.m (1.7 kgf-m, 12.5 ft-lb)