FixVault

Inhibitor Switch: Adjustment

  1. Set the select lever to "N" range.
  2. Loosen the three inhibitor switch securing bolts.
  3. Insert the ST as vertical as possible into the holes in the inhibitor switch lever and switch body.

    ST 499267300 STOPPER PIN

    Fig 1: Identifying Stopper Pin
    G05002513Courtesy of SUBARU OF AMERICA, INC.
  4. Tighten the three inhibitor switch securing bolts.

    Tightening torque: 

    3.4 N.m (0.35 kgf-m, 2.5 ft-lb) 

  5. Repeat the inspection of the inhibitor switch. If the inhibitor switch is determined to be "faulty", replace it.