FixVault

Fuel Sub Level Sensor: Inspection

  1. Measure the fuel sub level sensor float position.
    Fig 1: Measuring Fuel Sub Level Sensor Float Position
    G06351463Courtesy of SUBARU OF AMERICA, INC.
    FLOAT POSITION CHART

    Float position Standard
    FULL to Datum point (A) 5.31 ±3.5 mm (0.209±0.138 in)
    EMPTY to Datum point (B) 160.6 ±3.5 mm (6.323±0.138 in)
  2. Measure the resistance between fuel sub level sensor terminals.
Fig 2: Measuring Resistance Between Fuel Sub Level Sensor Terminals
G06344829Courtesy of SUBARU OF AMERICA, INC.
FLOAT POSITION CHART

Float position Terminal No. Standard
FULL (A) land 2 2.0±1.0 Ω
EMPTY (B) 62.1±1.0 Ω