FixVault

SI-DRIVE (SUBARU Intelligent Drive) Selector: Inspection

Measure the resistance between SI-DRIVE selector terminals.

Fig 1: Measuring Resistance Between SI-DRIVE Selector Terminals
G05340199Courtesy of SUBARU OF AMERICA, INC.
TERMINAL RESISTANCE REFERENCE

Switch position Terminal No. Standard value
Sport (when turning the SI-DRIVE selector to the left) 2 and 3 Less than 10 Ω
Intelligent (when pushing the SI-DRIVE selector) 0.8 -1.2 kΩ
Sport Sharp (when turning the SI-DRIVE selector to the right) 2.14 - 3.2 kΩ