FixVault

Starting System & Charging System (H4SO): Starter: Installation

Install in the reverse order of removal.

NOTE: For the MT model, a bolt is used in place (A).

Tightening torque: 50 N.m (5.1 kgf-m, 36.9 ft-lb) 

Fig 1: Identifying Starter And Transmission
G06648625Courtesy of SUBARU OF AMERICA, INC.

Tightening torque: 10 N.m (1.0 kgf-m, 7.4 ft-lb) 

Fig 2: Identifying Connector And Terminal
G05660070Courtesy of SUBARU OF AMERICA, INC.