FixVault

Intake Duct: Installation

WARNING: This page is about a different variant/trim than selected.
  1. Install the PCV hose assembly onto the intake duct.
    NOTE: Use a new clamp for the PCV hose assembly, fit the cut out in the ST with the protrusion on the clamp as shown in the illustration, and lock the clamp.

    ST 18353AA000 CLAMP PLIERS

    Fig 1: Pinching Clamp Of PCV Hose Assembly
    G07680905Courtesy of SUBARU OF AMERICA, INC.
    Fig 2: Locating PCV Hose Clamp
    G07680906Courtesy of SUBARU OF AMERICA, INC.
  2. Install the intake duct to the intake manifold.

    Tightening torque: 

    17 N.m (1.7 kgf-m, 12.5 ft-lb) 

    Fig 3: Locating Intake Duct Nut
    G07680907Courtesy of SUBARU OF AMERICA, INC.
  3. Install the sensor, engine harness and fuel pipe to the intake manifold. < Ref. to ASSEMBLY , Intake Manifold . >
  4. Install the intake manifold. < Ref. to INSTALLATION , Intake Manifold . >
  5. Connect the battery ground terminal.
    Fig 4: Connecting Ground Cable From Battery
    G07680908Courtesy of SUBARU OF AMERICA, INC.
  6. Install the collector cover.