Main Relay: Inspection
- Check that the main relay has no deformation, cracks or other damages.
- Measure the resistance between main relay terminals.TERMINALS RESISTANCE REFERENCE CHART
Terminal No. Standard 1 and 2 1 MΩ or more 3 and 4 130.4 - 230.8 Ω (When 20°C (68°F)) - Connect terminal No. 3 to battery positive terminal and terminal No. 4 to the battery ground terminal, and check the resistance between the main relay terminals.TERMINALS RESISTANCE REFERENCE CHART
Terminal No. Standard 1 and 2 Less than 1 Ω