FixVault

Normality Judgment

Judge as OK and clear the NG if the following conditions are established.

JUDGMENT VALUE CHART

Malfunction Criteria Threshold Value
Continuous time of (Target engine speed - Actual engine speed > -200 RPM) < 6000 ms
Continuous time of (actual retard amount > 20 °CA) < 0 ms

Time Needed for Diagnosis:  Less than 1 second



Judge as OK and clear the NG if the following conditions are established.

JUDGMENT VALUE CHART

Malfunction Criteria Threshold Value
Continuous time of (Standard ignition timing - Actual ignition timing > 0 °CA) > 1000 ms

Time Needed for Diagnosis:  1000 ms