Impact Sensitivity Adjustment
WARNING: This page is about a different car, the 2011 Subaru Tribeca. However, it is still accessible from the selected car via links, so may be relevant.
- Prepare the Subaru Select Monitor kit. Refer to PREPARATION TOOL PREPARATION TOOL, General Description.
- Prepare PC with Subaru Select Monitor installed.
- Connect USB cable to SDI (Subaru Diagnostic Interface) and PC USB port (Subaru Select Monitor dedicated port).NOTE: The dedicated port for the Subaru Select Monitor means the USB port which was used to install the Subaru Select Monitor.
- Connect the diagnosis cable to SDI.
- Connect SDI to data link connector located in the lower portion of the instrument panel (on the driver's side).CAUTION: Do not connect scan tools other than the Subaru Select Monitor.
- Start the PC.
- Turn the ignition switch to ON (engine OFF) and run the "PC application for Subaru Select Monitor III".
- On the System Selection Menu, select the {Impact Sensor}.
- Make a {Sensitivity Adjustment Mode}.
- Sensitivity can be adjusted in 11 levels (0 to 10).
- Initial setting is 5.
- Smaller number means more sensitive.
- Larger number means less sensitive.
- Turn the ignition switch to OFF, and then remove the Subaru Select Monitor.
NOTE:
- Set the sensor so as not to let the alarm on normal vibration (reclining to the door, hit the ball and etc.).
- Set the sensor to operate the alarm with hitting the door or window glass, etc. continuously like a mayhem by robbery.
- Ask the customer about parking situation for setting, because the alarm operate when the vibration not only the burglar but also the construction etc.