FixVault

Check Turn Signal And Hazard Module

  1. Measure the voltage between turn signal & hazard module connector and chassis ground.

    Preparation tool: Circuit tester Connector 

    Terminal No. Input/Output Inspection conditions Standard
    6 ↔ Chassis ground Input Turn signal switch (Right) OFF → ON 9 V or more → less than 1 V
    5 ↔ Chassis ground Input Turn signal switch (Left) OFF → ON 9 V or more → less than 1 V
    8 ↔ Chassis ground Input Hazard switch OFF → ON 9 V or more → less than 1 V
    2 ↔ Chassis ground Output Turn signal switch (Right) OFF → ON Repeat less than 1 V → less than 1 V ↔ more than 9 V at 60 to 120 times per minute.
    3 ↔ Chassis ground Output Turn signal switch (Left) OFF → ON Repeat less than 1 V → less than 1 V ↔ more than 9 V at 60 to 120 times per minute.
    2 ↔ Chassis ground Output Hazard switch OFF → ON Repeat less than 1 V → less than 1 V ↔ more than 9 V at 60 to 120 times per minute.
    3 ↔ Chassis ground Output Hazard switch OFF → ON Repeat less than 1 V → less than 1 V ↔ more than 9 V at 60 to 120 times per minute.
  2. Replace the turn signal and hazard module if the inspection result is not within the standard value.