FixVault

Read Current Data: List

Items to be displayed Unit of measure Remarks Note
Engine Speed rpm Data value received by CAN -
Heater Control Panel Setting Value (Driver's) LO: 18°C (64°F)
HI: 32°C (90°F)
Control panel display value Auto A/C
Heater Control Panel Setting Value (Passenger's) LO: 18°C (64°F)
HI: 32°C (90°F)
Control panel display value Auto A/C
Blower outlet Door Request Temperature °C (°F) A/C CM internal setting value Auto A/C
Blower outlet request temperature (Driver's) °C (°F) A/C CM internal setting value Auto A/C
Blower outlet request temperature (Passenger's) °C (°F) A/C CM internal setting value Auto A/C
Blower Fan Operating Condition MANU/AUTO A/C CM input value Auto A/C
A/C Operating Condition MANU/AUTO A/C CM input value Auto A/C
Fresh/Recircle Air Operating Condition MANU/AUTO A/C CM input value Auto A/C
Mode Operating Condition MANU/AUTO A/C CM input value Auto A/C
Rear Defogger ON/OFF A/C CM input value -
In-vehicle Sensor Temperature °C (°F) A/C CM input value Auto A/C
Evaporator Temperature °C (°F) A/C CM input value -
Quantity of Sunload W/m2 A/C CM input value Auto A/C
Refrigerant Pressure MPa A/C CM input value -
Refrigerant Flow kg/h A/C CM input value -
Air mix door actuator position (driver's side) % A/C CM input value -
Air mix door actuator position (passenger's side) % A/C CM input value Auto A/C
Fresh/Recircle Air Door Actuator Position % A/C CM input value -
Mode Door Actuator Position % A/C CM input value -
Heater Water Temperature °C (°F) Data value received by CAN -
Ambient Air Temperature °C (°F) Data value received by CAN -
Vehicle Speed km/h Data value received by CAN -
Accel. Opening Angle % Data value received by CAN -
Target air mix door actuator position (driver's side) % A/C CM input value -
Target air mix door actuator position (passenger's side) % A/C CM input value Auto A/C
Fresh/Recircle Air Door Actuator Position Target % A/C CM input value -
Mode Door Actuator Position Target % A/C CM input value -
Blower Fan Level Level A/C CM output value Auto A/C
Variable Flow Change Solenoid Duty % A/C CM output value -
Evaporator Temperature Target °C (°F) A/C CM input value -
Variable Load Compressor Torque Value Nm A/C CM input value -
Request idle engine speed rpm A/C CM output value -
Request engine speed 0: Without Request
1: Cooler H
2: Heater H
3: Cooler L
4: Heater L
A/C CM output value -
Discharge pressure MPa A/C CM input value -
Intake pressure MPa A/C CM input value -
Cooler request distinction Without Request/With Request A/C CM output value -
Heater request distinction Without Request/With Request A/C CM output value -
NOTE: For detailed operation procedures, refer to "PC application help for Subaru Select Monitor".