FixVault

Vacuum sensor assembly (FA20): Installation

  1. Installation of air pressure sensor assembly
    1. Attach a new O-ring to the air pressure sensor assembly.
    2. Apply engine oil to the O-ring.
    3. Using bolt, install the air pressure sensor assembly.

      Standard value: T=4.0N.m {41kgf.cm} {3.0ft.lbf}

    4. Connect the connector for air pressure sensor assembly.
  2. Installation of engine cover sub-assembly No. 1 (Refer to INSTALLATION )
  3. Connection of battery ground terminal

    Standard value: T=6.0N.m {61kgf.cm} {4.4 ft.lbf}