FixVault

Stop Light Switch: Removal

  1. Disconnect the ground cable from battery.
  2. Remove the instrument panel lower cover.
    1. Remove the clips, and remove the instrument panel side cover LH.
      Fig 1: Identifying Instrument Panel Side Cover LH Clips
      G06653104Courtesy of SUBARU OF AMERICA, INC.
    2. Remove the clips and data link connector, and remove the instrument panel lower cover under.
      Fig 2: Identifying Data Link Connector Clips
      G08583585Courtesy of SUBARU OF AMERICA, INC.
    3. Remove the bolts, and remove the knee guard panel.
      Fig 3: Locating Knee Guard Panel Mounting Bolts
      G08348746Courtesy of SUBARU OF AMERICA, INC.
    4. Remove the screws and clips and release the claws, and remove the instrument panel lower cover while disconnecting the harness connectors.
      Fig 4: Locating Instrument Panel Lower Cover Mounting Screws
      G06653106Courtesy of SUBARU OF AMERICA, INC.
  3. Remove the stop light switch.
    1. Disconnect the stop light switch connector (a).
    2. Remove the nut (b), and remove the stop light switch.
      Fig 5: Identifying Stop Light Switch Connector And Nuts
      G07915690Courtesy of SUBARU OF AMERICA, INC.