Basic Diagnostic Procedure
| Step | Check | Yes | No |
|---|---|---|---|
| 1 INITIAL CHECK. Check keyless entry system. |
Does the keyless entry system operate normally? | Go to step 2 . | Check keyless entry system. < Ref. to INSPECTION , Keyless Entry System. > |
2 CHECK SECURITY ON/OFF SETTING.
|
Is the security indicator light blinking patterns as follows?
|
Go to step 5 . | Go to step 3 . |
| 3 CHANGE SETTING OF SECURITY SYSTEM. Change the setting of security system to ON. < Ref. to SECURITY SYSTEM ON/OFF SETTING , INSPECTION, Security System. > |
Is setting change completed correctly? | Go to step 4 . |
|
4 CHECK SETTING CHANGE OF SECURITY SYSTEM.
|
Is the security indicator light blinking patterns as follows?
|
Go to step 5 . | Check the security indicator light circuit. < Ref. to CHECK SECURITY INDICATOR LIGHT CIRCUIT , INSPECTION, Security System. > |
| 5 CHECK SECURITY SYSTEM OPERATION. Press the LOCK button of keyless transmitter, and wait for 30 seconds. |
Does the security indicator light blink twice within 0.5 seconds in 2 second intervals? | Go to step 6 . | Replace the body integrated unit. < Ref. to BODY INTEGRATED UNIT . > |
6 CHECK SECURITY ALARM OPERATION.
|
Does the security alarm operate when opening any door or rear gate? | Go to step 7 . |
|
| 7 CHECK SECURITY ALARM OPERATION. Check the security alarm operation. |
Does all of the following security alarm operate?
|
Go to step 8 . |
|
| 8 CHECK SECURITY ALARM CANCEL OPERATION. Press any button of transmitter while operating security alarm. Or turn the ignition switch to OFF → ON once. |
Does all of the following security alarm stop?
|
Go to step 9 . | Check the ignition switch circuit. < Ref. to CHECK IGNITION SWITCH CIRCUIT , INSPECTION, Security System. > |
| 9 CHECK SECURITY SYSTEM CONDITION MEMORY. Check that the system functions properly even when the battery is not connected temporarily. < Ref. to CHECK SECURITY SYSTEM CONDITION MEMORY , INSPECTION, Security System. > |
Does the system function properly when the battery is not connected temporarily? | Go to step 10 . | Replace the body integrated unit. < Ref. to BODY INTEGRATED UNIT . > |
| 10 CHECK IMPACT SENSOR. Check the sensibility of impact sensor. < Ref. to CHECK IMPACT SENSOR , ADJUSTMENT, Impact Sensor. > |
Is the sensibility set properly? | Press the UNLOCK button of keyless transmitter, and finish the diagnosis. | Adjust the sensitivity. < Ref. to IMPACT SENSITIVITY ADJUSTMENT , ADJUSTMENT, Impact Sensor. > |
NOTE:
Check the function settings of the body integrated unit if any of the following symptoms appear. < Ref. to
BASIC DIAGNOSTIC PROCEDURE
. >
- The horn does not sound even when the security system operates.
- The horn sounds when setting the security to ON using the keyless transmitter.