FixVault

Judgment Value

JUDGMENT VALUE

Malfunction Criteria Threshold Value DTC
Average value of time necessary for λ to inverse the air fuel ratio to Lean → Rich → Lean. > 170 ms P015A
P015C
Average value of time necessary for λ to inverse the air fuel ratio to Rich → Lean → Rich. > 375 ms P015B
P015D

Time Needed for Diagnosis:  50 times of inversion

Malfunction Indicator Light Illumination:  Illuminates when malfunction occurs in 2 continuous driving cycles.

Judge as OK and clear the NG if the following conditions are established.



JUDGMENT VALUE

Malfunction Criteria Threshold Value DTC
Average value of time necessary for λ to inverse the air fuel ratio to Lean → Rich → Lean. ≤ 170 ms P015A
P015C
Average value of time necessary for λ to inverse the air fuel ratio to Rich → Lean → Rich. ≤ 375 ms P015B
P015D

Time Needed for Diagnosis:  50 times of inversion