Unit Inspection
- Inspection of trunk lock ASSY
- Operation check of trunk lock ASSY
- Set the latch of the trunk lock ASSY to the lock position.
- Check the motor operation when battery voltage is applied between the terminals of the connector.
CRITERIABattery connection Door lock operation Battery positive →1 (B)
Battery ground →2 (E)Lock →Open - Inspection of trunk lock ASSY courtesy switch
- Measure the resistance between the terminals.
RESISTANCEInspection terminals Inspection conditions Standard value Tester positive →2(E)
Tester negative →3(D+)Locked 10 kΩ or more Open Less than 1 Ω
- Operation check of trunk lock ASSY