  1. Check of back-up light switch ASSY
    1. Measure the resistance between the terminals.
      RESISTANCE

      Inspection terminals Inspection conditions Standard value
      1 - 2 When switch is pressed in Less than 1 Ω
      When switch is not pressed in 1 MΩ or more
      Fig 1: Measuring Resistance Between Back-Up Light Switch Assembly Terminals 1 - 2
      G08554855Courtesy of SUBARU OF AMERICA, INC.

      If the resistance is not within the normal value, replace the back-up light switch ASSY.