FixVault

Reprogramming Files For DTC P0420 (11-146-14)

Publication date: 2014-09-24
Reference number: 11-146-14

REPROGRAMMING FILES FOR DTC P0420

REPROGRAMMING FILES FOR DTC P0420

TECHNICAL SERVICE BULLETIN

Reference Number(s): 11-146-14, Date of Issue:  September 24, 2014
SUBARU: 2014-2015 Forester

APPLICABILITY

2014-15MY Forester 2.0 DIT Models

INTRODUCTION

This bulletin announces the availability of reprogramming files to address DTC P0420 which may set as a result of an incomplete ECM calculation during catalyst diagnosis.

COUNTERMEASURE IN PRODUCTION

The new logic was incorporated into production starting with VIN F*499037.

PACK FILE APPLICABILITY

MODEL/MODEL YEAR PAK FILE NAME NEW ECM PART NUMBER OLD ECM PART NUMBERS NEW CID NUMBER
2014-2015MY Forester 2.0L Turbo 22611AW066.pak 22611AW066 22611AW060, 061, 062, 063, 064, 065 AF56B00B
22765AG972.pak 22765AG972 22765AG970, 971 LF61500B
NOTE: SOA now highly recommends connecting the Midtronics GR8 Diagnostic Battery Charger to the vehicle and utilizing the Power Supply Mode feature anytime a vehicle control module is being reprogrammed. Once the GR8 is connected to the vehicle, as long as the battery is fully charged, it takes less than 3 minutes to boot-up the charger, select the Power Supply Mode, and have the battery voltage stabilized and ready for reprogramming.

VERY IMPORTANT:  This information is applicable to the Midtronics GR8 Diagnostic Battery Charger ONLY. It does not apply to any other brand/type of "generic" battery charger whatsoever. ONLY the GR8 and its Power Supply Mode feature has been tested and approved by Subaru of America, Inc. (SOA).

WARRANTY/CLAIM INFORMATION

For vehicles within the Basic New Car Limited and/or Emissions Warranty period, this repair may be claimed using the following information:

LABOR DESCRIPTION LABOR OPERATION # FAIL CODE LABOR TIME
MFI OBDII ECM Reprogramming A455-288 UPG-48 0.4

REMINDER:  SOA strongly discourages the printing and/or local storage of service information as previously released information and electronic publications may be updated at any time. Always refer to STIS for the latest service information before performing any repairs  .