FixVault

Judgment Value

JUDGMENT VALUE

Malfunction Criteria Threshold Value
Output terminal for heater characteristics failure detection Low

Time Needed for Diagnosis:  4 ms x 2500 time(s)

Malfunction Indicator Light Illumination:  Illuminates when malfunction occurs in 2 continuous driving cycles.

Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.



JUDGMENT VALUE

Malfunction Criteria Threshold Value
Output terminal for heater characteristics failure detection High

Time Needed for Diagnosis:  4 ms x 2500 time(s)