FixVault

Judgment Value

JUDGMENT VALUE

Malfunction Criteria Threshold Value DTC
Average value for λ amplitude > 0.055 P015A, P015B, P015C and P015D

Time Needed for Diagnosis:  11250 time(s) x 8 ms

Malfunction Indicator Light Illumination:  Illuminates when malfunction occurs in 2 continuous driving cycles.

Judge as OK and clear the NG if the following conditions are established.



JUDGMENT VALUE

Malfunction Criteria Threshold Value DTC
Average value for λ amplitude ≤ 0.055 P015A, P015B, P015C and P015D

Time Needed for Diagnosis:  11250 time(s) x 8 ms