FixVault

Normality Judgment

Judge as OK and clear the NG if the following conditions are established.

JUDGMENT VALUE

Malfunction Criteria Threshold Value
Estimated exhaust gas temperature ≥ Value of Map 4

Time Needed for Diagnosis:  Less than 1 second



Judge as OK and clear the NG if the following conditions are established.

JUDGMENT VALUE

Malfunction Criteria Threshold Value
Actual engine speed - Target engine speed ≥ - 125 rpm

Time Needed for Diagnosis:  5000 ms



Judge as OK and clear the NG if the following conditions are established.

JUDGMENT VALUE

Malfunction Criteria Threshold Value
Final ignition timing - ignition timing during CSERS*
*: Ignition timing during CSERS (Cold Start Emission Reduction Strategy) = Base ignition timing - retard amount
≤ Value of Map 5

Time Needed for Diagnosis:  5000 ms