Variant Work
Perform when replacing the combination meter assembly.
- When communication with Subaru Select Monitor is possible («Read Control module setting information» is workable): Perform the operation procedure A.
- When communication with Subaru Select Monitor is not possible («Read Control module setting information » is not workable): Perform the operation procedure B.
CAUTION:
- Subaru Select Monitor is required for variant work.
- If an error is displayed during the work, click the «OK» button and perform the variant work again.
Operation procedure A
- Connect the Subaru Select Monitor.
- On «Main Menu» display, select «Each System Check».
- On «System Selection Menu» display, select «Combination Meter».
- On «Control module settings» display, select «Read Control module setting information».
- Save and close the file.
- Replace the combination meter assembly with a new part.
- On «Main Menu» display, select «Each System Check».
- On «System Selection Menu» display, select «Combination Meter».
- On «Control module settings» display, select «Write Control module setting information».
- Select «Write ECU setting save data», and open the file stored in «Read Control module setting information».
- When the confirmation screen indicating the vehicle information appears, check that the correct information is displayed and click the «OK» button.
- Confirm that «Write operation was completed.» is displayed, and click the «OK» button.
Operation procedure B
- Replace the combination meter assembly with a new part.
- Connect the Subaru Select Monitor.
- On «Main Menu» display, select «Each System Check».
- On «System Selection Menu» display, select «Combination Meter».
- On «Control module settings» display, select «Write Control module setting information».
- On «Read Control module setting information» display, select «Write ECU setting 12 columns of models».
Enter the applied model and click the «OK» button. <Ref. to IDENTIFICATION NUMBER & LABEL LOCATIONS , IDENTIFICATION, Identification.>
- Enter the option code and click the «OK» button. <Ref. to IDENTIFICATION NUMBER & LABEL LOCATIONS , IDENTIFICATION, Identification.>
- Confirm the vehicle information on «Write ECU setting 12 columns of models» display and click the «OK» button.
- When «Write?» is shown on the screen, click the «Yes» button.
- Confirm that «Write operation was completed.» is displayed, and click the «OK» button.