  1. Install the front exhaust pipe.
    NOTE: Use a new gasket.

    Tightening torque: 

    40 N.m (4.1 kgf-m, 29.5 ft-lb) 

    Fig 1: Locating Front Exhaust Pipe Bolts
    G10265497Courtesy of SUBARU OF AMERICA, INC.
    Fig 2: Locating Front Exhaust Pipe Bolts
    G10265498Courtesy of SUBARU OF AMERICA, INC.
  2. Install the joint pipe to the exhaust manifold RH.
    NOTE: Use a new gasket.

    Tightening torque: 

    42.5 N.m (4.3 kgf-m, 31.3 ft-lb) 

    Fig 3: Locating Exhaust Manifold RH Joint Pipe Bolts
    G04998841Courtesy of SUBARU OF AMERICA, INC.
  3. Install the exhaust manifold RH lower cover and exhaust manifold LH cover.

    Tightening torque: 

    19 N.m (1.9 kgf-m, 14.0 ft-lb) 

    Fig 4: Locating Exhaust Manifold RH And LH Cover Bolts
    G05660991Courtesy of SUBARU OF AMERICA, INC.
  4. Install the front oxygen (A/F) sensor. <Ref. to INSTALLATION , Front Oxygen (A/F) Sensor.>
  5. Install the under cover. <Ref. to INSTALLATION , Front Under Cover.>
  6. Lower the vehicle.
  7. Connect the battery ground terminal.