FixVault

Monitor strategy

Related DTCs P0420: Catalyst monitor with sufficient sensor performance for other monitors functional check
Required Sensors/Components (Main) Air/fuel ratio and oxygen sensors
Required Sensors/Components (Related) Intake air temperature sensor, intake air flow meter sub-assembly, vacuum sensor, crankshaft position sensor, and E.F.I. water temperature sensor
Frequency of Operation Once per driving cycle
Duration 30 to 55 seconds
MIL Operation 2 operation cycle
Sequence of Operation None