FixVault

Unit Inspection

  1. Check of select lever Assembly
    1. Measure the resistance between the terminals.

      Resistance

      Inspection terminals Inspection conditions (shift position) Standard value
      1 - 3 Select lever in any other than P position Less than 1 Ω
      2 - 3 Select lever in P position
      8 - 9 When select lever is in M position and shifted to "+"
      10 - 11 Select lever in M position
      12 - 13 When select lever is in M position and shifted to "-"
      1 - 3 Select lever in P position 10 k Ωor more
      2 - 3 Select lever in any other than P position
      8 - 9 Except when select lever is in M position and shifted to "+"
      10 - 11 Select lever in any other than M position
      12 - 13 Except when select lever is in M position and shifted to "-"
      Fig 1: Select Lever Assembly Connector Terminal Identification
      G10214349Courtesy of SUBARU OF AMERICA, INC.
  2. Check of shift lock solenoid Assembly
    1. Measure the resistance between the terminals.

      Resistance

      Inspection terminals Inspection conditions Standard value
      4 - 5 20°C 27.6 to 30.5 Ω
      Fig 2: Shift Lock Solenoid Assembly Connector Terminal Identification
      G10214350Courtesy of SUBARU OF AMERICA, INC.