FixVault

Check Motor

  1. Connect the battery positive terminal to terminal No. 2 and the battery ground terminal to terminal No. 1, and check that the valve is fully opened on LH side and the valve is fully closed on RH side.
    CAUTION: Do not power the motor for more than 10 seconds.
    Fig 1: Connecting Battery Positive Terminal To Terminal No. 2
    G10320595Courtesy of SUBARU OF AMERICA, INC.
  2. Connect the battery positive terminal to terminal No. 1 and the battery ground terminal to terminal No. 2, and check that the valve is fully closed on LH side and the valve is fully opened on RH side.
    CAUTION: Do not power the motor for more than 10 seconds.
    Fig 2: Connecting Battery Positive Terminal To Terminal No. 1
    G10320596Courtesy of SUBARU OF AMERICA, INC.