FixVault

Symptom Chart

Symptoms Repair order Reference
The door lock control system does not operate. 1. Remove and visually inspect the following fuses.
  • No. 3 (in fuse & relay box)
  • No. 7 (in fuse & relay box)
  • No. 15 (in fuse & relay box) (model without keyless access with push button start)
If the fuse is blown out, replace the fuse with a new part.
When there is no defective with the fuse, check the power supply and ground circuit. Ref. to SECURITY AND LOCKS > Door Lock Control System > CHECK POWER SUPPLY AND GROUND CIRCUIT .
2. Check the power supply and ground circuit for body integrated unit. Ref. to SECURITY AND LOCKS > Door Lock Control System > CHECK POWER SUPPLY AND GROUND CIRCUIT .
3. Check the door lock switch and the circuit. Ref. to SECURITY AND LOCKS > Door Lock Control System > CHECK DOOR LOCK SWITCH .
4. Check the rear gate opener button and the circuit. Ref. to SECURITY AND LOCKS > Door Lock Control System > CHECK REAR GATE OPENER BUTTON CIRCUIT .
5. Check the door lock actuator and the circuit. Ref. to SECURITY AND LOCKS > Door Lock Control System > CHECK DOOR LOCK ACTUATOR AND CIRCUIT .
A specific door lock actuator does not operate. Check the door lock actuator and circuit. Ref. to SECURITY AND LOCKS > Door Lock Control System > CHECK DOOR LOCK ACTUATOR AND CIRCUIT .