DIAGNOSTIC PROCEDURE

Step Check Yes No
1 CHECK OPERATION. 
Operate all power seat switches to check operation of each motor.
Does each motor rotate for one second or more when operating each switch? Go to step . Check the motor which does not operate.
2 CHECK SWITCH. 
  1. Disconnect the harness connector of power seat switch assembly.
  2. Measure resistance between all terminals of power seat switch assembly. < Ref. to CHECK POWER SEAT SWITCH , INSPECTION, Power Seat System. >
Does the inspection result show normal status with no problem? Replace the power seat control module. Replace the power seat switch assembly.