FixVault

Execution Condition

Secondary Parameters Execution condition
Battery voltage ≥ 10.9 V
Sub feedback In operation
Amount of intake air ≥ 10 g/s (0.35 oz/s)
Estimated temperature of the rear oxygen sensor element ≥ 500 °C (932 °F)
Enable conditions at interrupt control are as follows  
Air fuel ratio reduced from target air fuel ratio = Value of Map
Continuous time when rear oxygen sensor output voltage is less than 0.55 V ≥ 5000 ms
VOLTAGE SPECIFICATION - MAP

Output voltage of rear oxygen sensor V 0.0 0.15 0.2 0.4 0.6
Air fuel ratio reduced from target air fuel ratio % 15 15 4 4 4