FixVault

Body Integrated Unit: Installation

CAUTION: Before handling the airbag system components, refer to "CAUTION" of "General Description" in "AIRBAG SYSTEM". < Ref. to CAUTION , General Description. >
NOTE: Make sure that there are no differences from the contents of the current settings after installation. < Ref. to LIST , Read Current Data. >
  1. Install the body integrated unit.
  2. Install the relay & fuse box and fuse holder.

    Tightening torque: 

    Relay & fuse box: 7.5 N.m (0.8 kgf-m, 5.5 ft-lb) 

  3. Install the cover assembly - instrument panel LWR driver and the knee airbag module.
  4. Connect the battery ground terminal. < Ref. to BATTERY , NOTE, Note. >
    NOTE: For models other than STI model, connect the ground terminal to battery sensor.