FixVault

Inspection steps

  1. Check ignition switch circuit.
    1. Turn the ignition switch to OFF.
    2. Disconnect the ECM harness connector.
    3. Turn the ignition switch to ON.
    4. Measure the voltage between harness connector terminal and chassis ground.
    VOLTAGE SPECIFICATION

    Inspection terminals Inspection conditions Standard value
    A33-27 (IGSW) - chassis ground Always 10V or more

    NG: Check the fuse, or repair or replace the harness.

    OK: Check poor contact of connector.