DTC P0A3B Generator/alternator overheating: Notes
MONITOR STRATEGY
| Frequency of Operation | Consecutive |
| Duration | 1024 ms or more |
TYPICAL ENABLING CONDITIONS
| DTCs forbidding redundancy | None |
| LIN communication schedule is being executed | $01 |
TYPICAL MALFUNCTION THRESHOLDS
| Alternator internal failure flag (high temperature error) | ON |
| Alternator internal temperature monitor value | 168°C or more |