FixVault

Check Operation

  1. Check the mirror operation when battery voltage is applied between the connector terminals.
    Fig 1: Identifying Mirror Connector End View
    G10272729Courtesy of SUBARU OF AMERICA, INC.
    Terminal No. Inspection conditions Switch position
    - - OFF
    4 (+) - 3 (-) Apply battery voltage between terminals. UP
    3 (+) - 4 (-) Apply battery voltage between terminals. DOWN
    5 (+) - 4 (-) Apply battery voltage between terminals. LEFT
    4 (+) - 5 (-) Apply battery voltage between terminals. RIGHT
  2. If it does not operate normally, replace the outer mirror assembly.