FixVault

Diagnostic Method

Judge as NG when one of the following conditions is established.

JUDGMENT VALUE SPECIFICATION

Malfunction Criteria Threshold Value
(1) Main throttle opening angle - Main throttle opening angle at monitoring start ≥ 2 °
(2) Monitoring IC motor continuity cut demand None
(3) Monitoring IC register writing value Reading value

Time Needed for Diagnosis: 

  1. 24 ms
  2. 2984 ms = (25 + 6) x 0.008 + (4 x 25 + 4) x 0.008 + (5 x 25 + 9) x 0.008 + (2 x 25) x 0.008 + (25 + 2) x 0.008 x 2
  3. 200 ms

Malfunction Indicator Light Illumination:  Illuminates as soon as a malfunction occurs.