Starting System & Charging System (H6DO): Generator: Installation

  1. Install the generator bracket to the engine.

    Tightening torque: 

    36 N.m (3.7 kgf-m, 26.6 ft-lb) 

  2. Temporarily attach the bolts (A) and generator plate (B) to the generator.
  3. Temporarily fit the generator in the groove (C) of the A/C compressor bracket.
    Fig 1: Identifying Generator Bolts, Plate And A/C Compressor Bracket And Groove
    G10264319Courtesy of SUBARU OF AMERICA, INC.
  4. Temporarily fit the collector cover bracket.
  5. Tighten the generator and collector cover bracket in the numerical order.

    Tightening torque: 

    T1: 6.4 N.m (0.7 kgf-m, 4.7 ft-lb) 

    T3: 25 N.m (2.5 kgf-m, 18.4 ft-lb) 

  6. Install the harness cover (C) to the collector cover bracket.
  7. Connect the connector (A) to the generator, and install the terminal (B).

    Tightening torque: 

    T2: 15 N.m (1.5 kgf-m, 11.1 ft-lb) 

    Fig 2: Installing Harness Cover To Collector Cover Bracket
    G10264320Courtesy of SUBARU OF AMERICA, INC.
  8. Install the tensioner assembly.

    Tightening torque: 

    20 N.m (2.0 kgf-m, 14.8 ft-lb) 

  9. Install the V-belts. Ref. to INSTALLATION , V-belt.
  10. Connect the ground terminal to battery sensor. Ref. to BATTERY
    NOTE: Repair Contents.
  11. Install the collector cover.