FixVault

Backup Battery

  1. Measure the voltage between connector terminals.

    Preparation tool: 

    Circuit tester 

    Fig 1: Backup Battery Connector Terminals
    G10270725Courtesy of SUBARU OF AMERICA, INC.
    Terminal No. Standard
    1 (+) - 2 (-) 2 V or more
  2. Replace the backup battery if the inspection result is not within the standard value.