Method With Timing Light
WARNING: This page is about a different variant/trim than selected.
- Before checking the ignition timing, check the following item:
- Check the air cleaner element is free from clogging, spark plugs are in good condition, and hoses are connected properly.
- Check the malfunction indicator light does not illuminate.
- Warm up the engine.
- Stop the engine, and turn the ignition switch to OFF.
- Disconnect the ground cable from battery.
- Remove the air intake duct. <Ref. to REMOVAL , Air Intake Duct.>
- Remove the air cleaner case. <Ref. to REMOVAL , Air Cleaner Case.>
- Connect the timing light to the power wire of #1 ignition coil.
- Install the air cleaner case. <Ref. to INSTALLATION , Air Cleaner Case.>
- Connect the battery ground terminal.
- Start the engine, turn the timing light to the crank pulley, and check the ignition timing through the timing belt cover gauge.NOTE: If ignition timing is out of standard, check the ignition control system. Refer to "Engine Control System". <Ref. to Basic Diagnostic Procedure .>
Ignition timing [BTDC/{r/min}]:
Standard
15°±10°/700
- After inspection, install the related parts in the reverse order of removal.