FixVault

Unit Inspection

  1. Check of select lever ASSY
    1. Measure the resistance between the terminals.

    Resistance

    Inspection terminals Inspection conditions (shift position) Standard value
    1 - 3 Select lever in any other than P position Less than 1 Ω
    2 - 3 Select lever in P position
    8 - 9 When select lever is in M position and shifted to "+"
    10 - 11 Select lever in M position
    12 - 13 When select lever is in M position and shifted to "-"
    1 - 3 Select lever in P position 10 k Ω or more
    2 - 3 Select lever in any other than P position
    8 - 9 Except when select lever is in M position and shifted to "+"
    10 - 11 Select lever in any other than M position
    12 - 13 Except when select lever is in M position and shifted to "-"
    G12587549Courtesy of SUBARU OF AMERICA, INC.
  2. Check of shift lock solenoid ASSY
    1. Measure the resistance between the terminals.

      Resistance

      Inspection terminals Inspection conditions Standard value
      4 - 5 20°C 27.6 to 30.5 Ω
      G12587550Courtesy of SUBARU OF AMERICA, INC.