FixVault

Unit Inspection

G12586468Courtesy of SUBARU OF AMERICA, INC.
  1. Inspection of oxygen sensor
    1. Measure the resistance between the terminals.
STANDARD VALUE RESISTANCE SPECIFICATION

Inspection terminals Inspection conditions Standard value
1 - 2 20°C {68°F} 5.0 to 6.4 Ω
1 - 4 Always 10 k Ω or more