FixVault

Cooling System

ENGINE COOLING SYSTEM SPECIFICATION

Cooling System Electric Fan + Forced Engine Coolant Circulation System
Total Engine Coolant Capacity L (US qt, Imp qt) CVT model: Approx. 8.3 (8.8, 7.3)
MT model: Approx. 8.1 (8.6, 7.2)
Water Pump Type Centrifugal impeller type
Discharge performance Discharge rate L (US gal, Imp gal)/min 248 (65.5, 54.6)
Pump speed - Discharge pressure 8, 580 r/min - 88 kPa (8.9 mAq)
Engine coolant temperature 80°C (176°F)
Impeller diameter mm (in) 56 (2.2)
Number of impeller vanes 7
Pump pulley diameter mm (in) 100 (3.9)
Thermostat Type Wax pellet type
Starting temperature to open 86 - 90°C (187 - 194°F)
Fully opens 95°C (203°F)
Valve lift mm (in) 8.0 (0.315) or more
Valve opening size mm (in) 32 (1.26)
Radiator Fan Motor input Main fan W 120
Sub fan W 120
Fan diameter/Blade Main fan 320 mm (12.6 in)/9
Sub fan 320 mm (12.6 in)/11
Radiator Type Down flow, pressure type
Core dimensions Width x Height x Thickness mm (in) 687.4 x 340 x 16
(27.06 x 13.39 x 0.63)
Pressure range in which cap valve is open kPa (kg/cm2 , psi) Positive pressure side Standard 93 - 123 (0.95 - 1.25, 14 - 18)
Limit 83 (0.85, 12)
Negative pressure side Standard -1.0 to -4.9 or less
(-0.01 --0.05, -0.1 --0.7)
Fins Corrugated fin type
Reservoir Tank Capacity L (US qt, Imp qt) 0.45 (0.48, 0.40)