Radiator Fan System: Inspection
Operating Condition:
| VEHICLE SPEED | A/C COMPRESSOR LOAD | ENGINE COOLANT TEMPERATURE | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| INCREASE: 94°C (201°F) or LESS DECREASE: 92°C (198°F) or LESS |
INCREASE: 95 - 99°C (203 - 210°F) DECREASE: 93 - 94°C (199 - 201°F) |
INCREASE: 100°C (212°F) or MORE DECREASE: 95°C (203°F) or MORE |
|||||||||
| RADIATOR FAN OPERATION | RADIATOR FAN OPERATION | RADIATOR FAN OPERATION | |||||||||
| During acceleration: 19 km/h (12 MPH) or less(1) During deceleration: 10 km/h (6 MPH) or less(1) |
OFF | OFF | Low-Speed | High-Speed | |||||||
| Low | Low-Speed | Low-Speed | High-Speed | ||||||||
| High | High-Speed | High-Speed | High-Speed | ||||||||
| During acceleration: 20 - 69 km/h (12 - 43 MPH) During deceleration: 11 - 64 km/h (7 - 40 MPH) |
OFF | OFF | Low-Speed | High-Speed | |||||||
| Low | High-Speed | High-Speed | High-Speed | ||||||||
| High | High-Speed | High-Speed | High-Speed | ||||||||
| During acceleration: 70 - 134 km/h (43 - 83 MPH) During deceleration: 65 - 129 km/h (40 - 80 MPH) |
OFF | OFF | Low-Speed | High-Speed | |||||||
| Low | OFF(2) | Low-Speed(2) | High-Speed | ||||||||
| High | Low-Speed(2) | High-Speed | High-Speed | ||||||||
| During acceleration: 135 km/h (84 MPH) or more During deceleration: 130 km/h (81 MPH) or more |
OFF | OFF | OFF | High-Speed | |||||||
| Low | OFF | Low-Speed | High-Speed | ||||||||
| High | OFF | Low-Speed | High-Speed | ||||||||
|
|||||||||||
Diagnosis:
Radiator main fan and radiator sub fan do not rotate under the above operating conditions.
- CHECK OPERATION OF RADIATOR FAN
.
- Install the delivery mode fuse.
- Turn the ignition switch to ON.
- Using the Subaru Select Monitor, perform the active test for the radiator fan relay.NOTE:
- When performing the active test for the radiator fan relay using the Subaru Select Monitor, the radiator main fan and radiator sub fan will repeat low speed revolution → high speed revolution → OFF in this order.
- For detailed operation procedures of Subaru Select Monitor 4, refer to "Application Help".
Do the radiator main fans and radiator sub fans rotate at low speed?
Yes: Go to 2.
No: Go to 3.
- CHECK OPERATION OF RADIATOR FAN
.
Using the Subaru Select Monitor, perform the active test for the radiator fan relay.
NOTE:- When performing the active test for the radiator fan relay using the Subaru Select Monitor, the radiator main fan and radiator sub fan will repeat low speed revolution → high speed revolution → OFF in this order.
- For detailed operation procedures of Subaru Select Monitor 4, refer to "Application Help".
Do the radiator main fans and radiator sub fans rotate at high speed?
Yes: Radiator main fan system is normal.
No: Go to 27.
- CHECK POWER SUPPLY TO SUB FAN RELAY
.
- Turn the ignition switch to OFF.
- Remove the sub fan relay.
- Measure the voltage between the sub fan relay terminal and chassis ground.
Connector & terminal
(F27) No. 17 (+) - Chassis ground (-):
Is the voltage 10 V or more?
Yes: Go to 4.
No: Go to 5.
- CHECK POWER SUPPLY TO SUB FAN RELAY
.
- Turn the ignition switch to ON.
- Measure the voltage between the sub fan relay terminal and chassis ground.
Connector & Terminal
(F27) No. 20 (+) - Chassis ground (-):
Is the voltage 10 V or more?
Yes: Go to 7.
No: Go to 6.
- CHECK FUSE
.
- Remove the fuse No. 3.
- Check the condition of fuse.
Is the fuse blown out?
Yes: Replace the fuse.
No: Repair the power supply line.
- CHECK FUSE
.
- Turn the ignition switch to OFF.
- Remove the fuse No. 22.
- Check the condition of fuse.
Is the fuse blown out?
Yes: Replace the fuse.
No: Repair the power supply line.
- CHECK SUB FAN RELAY
.
Measure the resistance between sub fan relay switch terminals.
Is the resistance 1 MΩ or more?
Yes: Go to 8.
No: Replace the sub fan relay. Ref. to HVAC SYSTEM (HEATER, VENTILATOR AND A/C)>Relay and Fuse .
- CHECK SUB FAN RELAY
.
- Connect the battery to the terminal on the sub fan relay coil side.
- Measure the resistance between sub fan relay switch terminals.
Is the resistance less than 1 Ω?
Yes: Go to 9.
No: Replace the sub fan relay. Ref. to HVAC SYSTEM (HEATER, VENTILATOR AND A/C)>Relay and Fuse .
- CHECK HARNESS BETWEEN SUB FAN RELAY TERMINAL AND SUB FAN MOTOR CONNECTOR
.
- Turn the ignition switch to OFF.
- Disconnect the connector from the sub fan motor.
- Measure the resistance of harness between the sub fan relay terminal and sub fan motor connector.
Connector & Terminal
(F16) No. 1 - (F27) No. 18:
Is the resistance less than 1 Ω?
Yes: Go to 10.
No: Repair the open circuit of harness between sub fan relay terminal and sub fan motor connector.
- CHECK HARNESS BETWEEN SUB FAN MOTOR CONNECTOR AND MAIN FAN RELAY 2 CONNECTOR
.
- Remove the main fan relay 2.
- Measure the resistance of harness between sub fan motor connector and main fan relay 2 connector.
Connector & Terminal
(F16) No. 2 - (F27) No. 12:
Is the resistance less than 1 Ω?
Yes: Go to 11.
No: Repair the open circuit of the harness between sub fan motor connector and main fan relay 2 connector.
- CHECK FOR POOR CONTACT
.
Check poor contact of sub fan motor connector.
Is there poor contact of the sub fan motor connector?
Yes: Repair the poor contact of sub fan motor connector.
No: Go to 12.
- CHECK SUB FAN MOTOR
.
Connect the battery positive (+) terminal to terminal No. 1 of the sub fan motor, and the ground (-) terminal to terminal No. 2.
Does the radiator sub fan rotate?
Yes: Go to 13.
No: Replace the sub fan motor. Ref. to COOLING(EXCEPT FOR STI)>Radiator Sub Fan and Fan Motor .
- CHECK MAIN FAN RELAY 2
.
Measure the resistance between terminals of main fan relay 2 switch (always ON side).
Is the resistance less than 1 Ω?
Yes: Go to 14.
No: Replace the main fan relay 2. Ref. to HVAC SYSTEM (HEATER, VENTILATOR AND A/C)>Relay and Fuse .
- CHECK HARNESS BETWEEN MAIN FAN RELAY 2 AND MAIN FAN MOTOR CONNECTOR
.
- Disconnect the connector from the main fan motor.
- Measure the resistance of the harness between main fan relay 2 terminal and main fan motor connector.
Connector & Terminal
(F17) No. 1 - (F27) No. 14:
Is the resistance less than 1 Ω?
Yes: Go to 15.
No: Repair the open circuit of the harness between main fan relay 2 terminal and main fan motor connector.
- CHECK GROUND CIRCUIT OF MAIN FAN MOTOR
.
Measure the resistance between main fan motor connector and chassis ground.
Connector & Terminal
(F17) No. 2 - Chassis ground:
Is the resistance less than 5 Ω?
Yes: Go to 16.
No: Repair the open circuit of the harness between main fan motor connector and chassis ground.
- CHECK FOR POOR CONTACT
.
Check poor contact of main fan motor connector.
Is there poor contact of the main fan motor connector?
Yes: Repair the poor contact of main fan motor connector.
No: Go to 17.
- CHECK MAIN FAN MOTOR
.
Connect the battery positive (+) terminal to terminal No. 1 of the main fan motor, and the ground (-) terminal to terminal No. 2.
Does the radiator main fan rotate?
Yes: Go to 18.
No: Replace the main fan motor. Ref. to COOLING(EXCEPT FOR STI)>Radiator Main Fan and Fan Motor .
- CHECK HARNESS BETWEEN SUB FAN RELAY AND ECM
.
- Disconnect the connector from ECM.
- Measure the resistance between the sub fan relay terminal and ECM connector.
Connector & Terminal
(B134) No. 25 - (F27) No. 19:
Is the resistance less than 1 Ω?
Yes: Go to 19.
No: Repair the open circuit of harness between sub fan relay terminal and ECM.
- CHECK FOR POOR CONTACT
.
Check for poor contact of ECM connector.
Is there poor contact of ECM connector?
Yes: Repair the poor contact of ECM connector.
No: Check the DTC. Repair the trouble cause. Ref. to ENGINE (DIAGNOSTICS) (EXCEPT FOR STI)>Read Diagnostic Trouble Code (DTC) .
- CHECK MAIN FAN RELAY 1
.
- Turn the ignition switch to OFF.
- Remove the main fan relay 1.
- Measure the resistance between terminals of main fan relay 1 switch.
Is the resistance 1 MΩ or more?
Yes: Go to 21.
No: Replace the main fan relay 1. Ref. to HVAC SYSTEM (HEATER, VENTILATOR AND A/C)>Relay and Fuse .
- CHECK MAIN FAN RELAY 1
.
- Connect the main fan relay 1 coil side terminal to the battery.
- Measure the resistance between terminals of main fan relay 1 switch.
Is the resistance less than 1 Ω?
Yes: Go to 22.
No: Replace the main fan relay 1. Ref. to HVAC SYSTEM (HEATER, VENTILATOR AND A/C)>Relay and Fuse .
- CHECK HARNESS BETWEEN MAIN FAN RELAY 1 AND MAIN FAN MOTOR CONNECTOR
.
- Disconnect the connector from the main fan motor.
- Measure the resistance of the harness between main fan relay 1 terminal and main fan motor connector.
Connector & Terminal
(F17) No. 1 - (F36) No. 6:
Is the resistance less than 1 Ω?
Yes: Go to 23.
No: Repair the open circuit of the harness between main fan relay 1 terminal and main fan motor connector.
- CHECK HARNESS BETWEEN MAIN FAN RELAY 1 AND ECM
.
- Disconnect the connector from ECM.
- Measure the resistance between main fan relay 1 terminal and ECM connector.
Connector & Terminal
(B134) No. 37 - (B143) No. 7:
Is the resistance less than 1 Ω?
Yes: Go to 24.
No: Repair the open circuit of the harness between main fan relay 1 terminal and ECM.
- CHECK HARNESS BETWEEN MAIN FAN RELAY 2 AND ECM
.
Measure the resistance between main fan relay 2 terminal and ECM connector.
Connector & Terminal
(B134) No. 37 - (F27) No. 15:
Is the resistance less than 1 Ω?
Yes: Go to 25.
No: Repair the open circuit of the harness between main fan relay 2 terminal and ECM.
- CHECK FUSE
.
- Remove the fuse No. 2 and No. 26.
- Check the condition of fuse.
Is the fuse blown out?
Yes: Replace the fuse.
No: Go to 26.
- CHECK FOR POOR CONTACT
.
Check for poor contact of ECM connector.
Is there poor contact of ECM connector?
Yes: Repair the poor contact of ECM connector.
No: Repair the power supply circuit to the main fuse box.
- CHECK OPERATION OF RADIATOR FAN
.
If the both fans do not rotate at high speed in the condition of step 2, check whether the radiator sub fan is rotating.
Does the radiator sub fan rotate?
Yes: Go to 20.
No: Go to 28.
- CHECK GROUND CIRCUIT OF MAIN FAN RELAY 2
.
- Turn the ignition switch to OFF.
- Remove the main fan relay 2.
- Measure the resistance between main fan relay 2 terminal and chassis ground.
Connector & Terminal
(F27) No. 13 - Chassis ground:
Is the resistance less than 1Ω?
Yes: Go to 29.
No: Repair the open circuit of harness between main fan relay 2 and chassis ground.
- CHECK POWER SUPPLY TO MAIN FAN RELAY 2
.
- Turn the ignition switch to ON.
- Measure the voltage between main fan relay 2 terminal and chassis ground.
Connector & Terminal
(F27) No. 16 (+) - Chassis ground (-):
Is the voltage 10 V or more?
Yes: Go to 30.
No: Repair the power supply line.
- CHECK MAIN FAN RELAY 2
.
Measure the resistance between terminals of main fan relay 2 switch (always OFF side).
Is the resistance 1 MΩ or more?
Yes: Go to 31.
No: Replace the main fan relay 2. Ref. to HVAC SYSTEM (HEATER, VENTILATOR AND A/C)>Relay and Fuse .
- CHECK MAIN FAN RELAY 2
.
- Connect the main fan relay 2 coil side terminal to the battery.
- Measure the resistance between terminals of main fan relay 2 switch (always OFF side).
Is the resistance less than 1 Ω?
Yes: Go to 23.
No: Replace the main fan relay 2. Ref. to HVAC SYSTEM (HEATER, VENTILATOR AND A/C)>Relay and Fuse .