FixVault

Oil Control Solenoid: Inspection

  1. Check that the oil control solenoid has no deformation, cracks or other damages.
  2. Measure the resistance between the oil control solenoid terminals.
    G08315385
    TERMINAL NO. STANDARD
    1 and 2 7.25±0.4 Ω (when 20°C (68°F))