FixVault

Reservoir Tank: Installation

  1. Install the reservoir - tank assembly.

    Tightening Torque: 

    13 N.m (1.3 kgf-m, 9.6 ft-lb)

  2. Connect the hose - suction and the hose - return to the reservoir - tank assembly.
  3. Replenish power steering fluid up to the specified level. Ref. to POWER ASSISTED SYSTEM (POWER STEERING)>Power Steering Fluid>INSPECTION