Unit Inspection
LOCK ASSY - FUEL
- Check lock assembly - fuel
Check the fuel lock operation when battery voltage is applied between the connector terminals.
Preparation tool:
Circuit tester
Terminal No. Inspection conditions Specification 1 (+) - 2 (-) Connect battery to the terminals OPEN - Replace the lock assembly - fuel if faulty is found in the inspection.
FUEL FLAP STATUS SWITCH
- Check fuel flap status switch
Measure the resistance between connector terminals.
Preparation tool:
Circuit tester
Terminal No. Inspection conditions Standard 1 - 2 When the switch is not pressed Less than 1 Ω When the switch is pressed 1 MΩ or more - Replace the saucer - COMPL if faulty is found in the inspection.
REFUELING REQUEST SWITCH
- Measure the resistance between connector terminals.
Preparation tool:
Circuit tester
Terminal No. Inspection conditions Standard 1 - 4 OFF 1 MΩ or more ON Less than 1 Ω - Apply battery voltage between the connector terminals to check lighting condition of illumination inside the switch.CAUTION: When applying battery voltage, do not mix up the positive (+) side and the negative (-) side.
Incorrect polarity connection may cause LED damage inside the switch.Terminal No. Inspection conditions Specification 2 (+) - 3 (-) Apply battery voltage. Light ON - Replace the refueling request switch if faulty is found in the inspection.