Auto Start Stop DC/DC CONVERTER 2

  1. Disconnect the ground cable from battery. Ref. to REPAIR CONTENTS>NOTE>BATTERY .
  2. Disconnect the connector from the Auto Start Stop DC/DC converter 1 and Auto Start Stop DC/DC converter 2, and remove the clips.
    G13224916Courtesy of SUBARU OF AMERICA, INC.
  3. Remove the Auto Start Stop DC/DC converter 1 and the Auto Start Stop DC/DC converter 2.
    G13224917Courtesy of SUBARU OF AMERICA, INC.
  4. Remove the bracket.
G13224918Courtesy of SUBARU OF AMERICA, INC.