FixVault

Execution Condition

Secondary parameters Execution condition
Battery voltage ≥ 10.9 V
Sub feedback In operation
Amount of intake air ≥10g/s (0.35oz/s)
Estimated temperature of the rear oxygen sensor element ≥500°C (932°F)
Enable conditions at interrupt control are as follows
Continuous time when rear oxygen sensor output voltage is less than 0.55V
≥15000 ms
Air fuel ratio reduced from target air fuel ratio = Value of Map

Map 

Output voltage of rear oxygen sensor (V) 0.00 0.15 0.20 0.40 0.60
Air fuel ratio reduced from target air fuel ratio (%) 15 15 4 4 4