FixVault

Diagnostic Method

Judge as NG when one of the following conditions is established.

Judgment1: 

JUDGMENT VALUE SPECIFICATION

Malfunction Criteria Threshold Value
(1) Main throttle position - Main throttle position when monitoring starts ≥ 2°

Judgment2: 

JUDGMENT VALUE SPECIFICATION

Malfunction Criteria Threshold Value
(2) Monitoring IC motor continuity cut demand Not detected

Judgment3: 

JUDGMENT VALUE SPECIFICATION

Malfunction Criteria Threshold Value
(3) Monitoring IC register writing value Reading value

Judgment4: 

JUDGMENT VALUE SPECIFICATION

Judgment1:
Malfunction Criteria Threshold Value
(4) Monitoring IC count up timer Does not change

Time needed for diagnosis: 

Judgment1: 24 ms

Judgment2: 2192 ms

Judgment3: 8time(s)

Judgment4: 200 ms

Malfunction indicator light illumination:  Illuminates as soon as a malfunction occurs.