Check Hood Switch
- Check switch
Measure the resistance between connector terminals.
Preparation tool:
Circuit tester
Terminal No. Inspection conditions Standard 1 - 2 Open the front hood 1 MΩ or more Close the front hood Less than 1 Ω - Replace the lock assembly front hood if the inspection result is not within the standard value.