FixVault

Initialization Procedures

NOTE:
  • Initialize the records inside the unit by performing all the following steps regardless the item order.
  • With each seat locked*, operating switches for 3 seconds makes the buzzer sound once.
  • If initialization is done after completing all items, the buzzer sounds three times when the last operation is completed and the switch is turned on then off.
  1. Move the seat rearward using the slide switch, and keep the seat lock* status for three seconds or more.
  2. Move the seat downward using the tilt switch, and keep the seat lock* status for three seconds or more.
  3. Move the seat downward using the lifter switch, and keep the seat lock* status for three seconds or more.
  4. Move the seat back forward using the reclining switch, and keep the seat lock* status for three seconds or more.

    *: Seat lock is the status that there is no pulse output from the encoder within the specified period of time with the switch operated though the seat reaches the movable position end.

    NOTE: When the following conditions are met, the initializing operation is canceled even though the procedure is carried out halfway.
    • Interval between each initialization procedure of 1. to 4. exceeds 10 seconds.
    • If any of initialization procedures 1. to 4. are not performed.
    • The battery runs out or the voltage to the power seat control module falls out of the operation range during initialization.