Meter Pointer Operation Check
In meter pointer operation check, the meter operation, warning/indicator light, illumination and LCD/TFT are checked.
- After a buzzer sounds for 0.5 seconds and "STEP1" is displayed on LCD/TFT, the meter pointer operation check mode is initiated.
Time (sec) Meter indicator LCD/TFT display, illumination Warning light/indicator light 6 MIN indication
↓
MAX indicationILL1 (Min. brightness)
↓(4)
ILL6 (Max. brightness)(1), (2), (3) 6 MAX indication
↓
MIN indicationILL6 (Max. brightness)
↓(4)
ILL1 (Min. brightness)(1) Warning lights and indicator lights controlled by the meter drive circuit are illuminated. Ref. to INSTRUMENTATION/DRIVER INFO>General Description>SPECIFICATION . (2) Warning lights and indicator lights controlled by other module are turned on/off according to the module control. Ref. to INSTRUMENTATION/DRIVER INFO>General Description>SPECIFICATION . (3) Engine coolant temperature warning light illuminates in red. (4) Display for one second for each level.