FixVault

Meter Pointer Operation Check

In meter pointer operation check, the meter operation, warning/indicator light, illumination and LCD/TFT are checked.

  1. After a buzzer sounds for 0.5 seconds and "STEP1" is displayed on LCD/TFT, the meter pointer operation check mode is initiated.
    Time (sec) Meter indicator LCD/TFT display, illumination Warning light/indicator light
    6 MIN indication

    MAX indication
    ILL1 (Min. brightness)
    (4)
    ILL6 (Max. brightness)
    (1), (2), (3)
    6 MAX indication

    MIN indication
    ILL6 (Max. brightness)
    (4)
    ILL1 (Min. brightness)
    (1) Warning lights and indicator lights controlled by the meter drive circuit are illuminated. Ref. to INSTRUMENTATION/DRIVER INFO>General Description>SPECIFICATION .

    (2) Warning lights and indicator lights controlled by other module are turned on/off according to the module control. Ref. to INSTRUMENTATION/DRIVER INFO>General Description>SPECIFICATION .

    (3) Engine coolant temperature warning light illuminates in red.

    (4) Display for one second for each level.